ENCORE Multi-Neutral Mc CableEncore Multi Neutral Mc Cable

Installation costs reduced up to 50% over conduit and wire. Insulating anti-short bushings are supplied with each reel or coil. SmartColorID® labels are spaced are regular intervals on the exterior of the metal sheathing and are removable. For ease of installation and pulling, cable is reverse wound on reels. Coils are designed to be pulled from the inside.

Engineering Specifications: Standards: Underwriters Laboratories Standards UL-83, UL-1569 for type MC, NEMA WC 70/ICEA 5-95-658, Federal Specification A-A59544, IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame Test, the National Electrical Code (NEC), and ARRA 2009; Section 1605 "Buy American" Compliant Applications: Type MC cable shall be permitted as follows:

  • Permitted multiple circuits use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings
  • Acceptable for power, lighting, control, and signal circuits
  • Allowable in concealed or exposed systems
  • Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations
  • Utilized for environmental air-handling spaces (NEC 300.22)(C)
  • Allowable in assembly occupancies (NEC 518.4)
  • Permissible in theaters, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)
  • Allowable installations in approved raceways and cable trays (NEC 392)
  • Suitable for installation under raised floors for IT equipment (NEC 645.5)
  • Permitted in Class I Div. 2, Class II Div. 2, and Class III Div. 1 Hazardous Locations
  • Listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems
Construction: Available in sizes 12 AWG and 10 AWG with oversized neutral conductors or one neutral per phase and two insulated ground conductors. Encore Wire Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90°C dry locations. All conductors are cabled together with a separator tape containing the identification print legend to form the cable core. Interlocked steel armor is applied over the entire assembly.